Microwave Motion Sensor T8 LED Tube

This G13 T8 LED tube integrates a high-frequency microwave motion sensor with adjustable hold time and standby output. Three indoor models cover 590, 1199 and 1499 mm lengths for parking, warehouse and circulation-area lighting.
  • Activity-Based Energy Saving: Sleeping behavior reduces unnecessary full-output operation in intermittently occupied areas by up to 95%.
  • Controlled Fade-Back Timing: The waiting period prevents an immediate return to the reduced state after a brief pause in movement.
  • Background Wayfinding: The lower-output state preserves orientation light between full-brightness events.
  • Compact Automatic Lamp: Sensing and illumination share one replaceable tubular form instead of separate lamp and detector products.
Sensor & ResponseHigh-frequency microwave motion sensor; instant start
Mounting & Detection3-4.5 m recommended height; 5-8 m radius; approx. 120 degrees
Hold Time45 s standard; configurable up to 3 min
Standby Output3 W standard; configurable 1-10 W
Size & Rated PowerDia. 26 x L 590 / 1199 / 1499 mm; 9 / 18 / 22 W; G13
Light & Electrical80-160 lm/W; 3000-8000 K; Ra70/80; no flicker; 25,000 h; AC 180-265 V or AC 85-265 V; PF 0.5/0.9; indoor

Technical Specifications

Model Specifications

Model No.Size Dia. x L (mm)PowerReplacementEfficacyCCT
XGYT8B102MS-E926 x 5909 W18 W80-160 lm/W3000-8000 K
XGYT8B104MS-E1826 x 119918 W36 W80-160 lm/W3000-8000 K
XGYT8B105MS-E2226 x 149922 W58 W80-160 lm/W3000-8000 K

Recommended sensor installation: 3-4.5 m height, 5-8 m radius and approximately 120-degree coverage. Standard hold time is 45 seconds, configurable up to 3 minutes; standby output is 3 W standard and configurable from 1 W to 10 W.

Product Description

Product Details

Product Construction

The 26 mm G13 tube combines an opal diffuser, LED board, driver and a microwave sensor module positioned at the marked end collar. The sensor responds through the lamp body without requiring a separate detector on the ceiling.

Selection & Installation Notes

Choose the 590, 1199 or 1499 mm model and match its 9, 18 or 22 W rating to the fixture. Position the lamp within the recommended 3-4.5 m mounting height, then set hold time and standby output for the traffic pattern; metalwork, walls and movement outside the intended area can change the practical sensing zone.

Recommended Application

Applications

  • Parking Garages: Raise light output as vehicles or pedestrians move through protected indoor parking aisles.
  • Warehouse Aisles: Provide full light during activity and a lower standby level between visits to storage zones.
  • Service Corridors: Respond to intermittent foot traffic in indoor back-of-house and utility circulation areas.
  • Indoor Stairwells: Trigger light as people enter enclosed stair and landing areas with compatible linear fixtures.
Keep
in touch

Tell Us Your Market and Product Needs

Share your market, product interest, application, or estimated quantity. Our team can help you move faster from product selection to quotation and sample discussion.

By submitting this form, you ask New Lights Lighting Technology Co., Ltd. to use the information you provide to respond to your inquiry and manage related business communications. See our Privacy Policy. Optional marketing emails require the separate choice below.

Frequently Asked Questions?

Find clear answers to common questions about product specifications, model selection, applications, and quotation requirements. For project-specific needs, send us your target market, required quantity, and key specifications.

How does the microwave sensor T8 tube respond to movement?

The built-in high-frequency microwave module detects movement and triggers instant full-light operation within the configured sensing and timing settings.

What mounting height and detection range are recommended?

The catalog recommends a 3-4.5 m mounting height with a 5-8 m sensing radius and approximately 120-degree coverage.

Can the sensor hold time be adjusted?

Yes. The standard hold time is 45 seconds and can be configured up to 3 minutes.

Can the tube remain at a low light level when no movement is detected?

Yes. The standard standby level is 3 W and the supported configurable range is 1-10 W.

Can walls or fixture materials affect microwave detection?

Yes. Metalwork, room boundaries and movement outside the target zone can change the practical sensing pattern, so the installed lamp must be checked in its intended position.

Is this microwave sensor tube intended for outdoor use?

No. This series is for indoor use and does not have a stated outdoor or wet-location rating.

Featured Products

Scroll to Top

Send Us a Message

Leave your contact details and message. Our team will reply by email or through your preferred contact method.

By submitting this form, you ask New Lights Lighting Technology Co., Ltd. to use the information you provide to respond to your inquiry and manage related business communications. See our Privacy Policy. Optional marketing emails require the separate choice below.

Tell Us About Your Lighting Project

Share your product, application and purchasing requirements. Our lighting team will reply with suitable options and project support.

By submitting this form, you ask New Lights Lighting Technology Co., Ltd. to use the information you provide to respond to your inquiry and manage related business communications. See our Privacy Policy. Optional marketing emails require the separate choice below.