| Fixture Formats | Single tube / double tube |
|---|---|
| Lengths & Rated Power | 590-1500 mm / 9-44 W |
| Input Options | S: AC 180-265 V / PF >0.5; U: AC 85-265 V / PF >0.9 |
| Light Options | 80-160 lm/W; 3000-8000 K; CRI 70 / 80 / 90 / 95 / 97 |
|---|---|
| Installation | Surface mounted with screw-fixing connector blocks |
| Connection Options | Cable or socket input; interconnectable version available |
Technical Specifications
Model Specifications
| Model No. | Format | Tube D x L (mm) | Rated Power | Fluorescent EqV. | Input Voltage | Efficacy | CCT / CRI |
|---|---|---|---|---|---|---|---|
| XGYT8B102SL-E9 | Single | 26 x 590 | 9 W | 18 W | S: 180-265 V; U: 85-265 V | 80-160 lm/W | 3000-8000 K / 70-97 |
| XGYT8B103SL-E12 | Single | 26 x 895 | 12 W | 30 W | S: 180-265 V; U: 85-265 V | 80-160 lm/W | 3000-8000 K / 70-97 |
| XGYT8B104SL-E18 | Single | 26 x 1199 | 18 W | 36 W | S: 180-265 V; U: 85-265 V | 80-160 lm/W | 3000-8000 K / 70-97 |
| XGYT8B105SL-E22 | Single | 26 x 1500 | 22 W | 58 W | S: 180-265 V; U: 85-265 V | 80-160 lm/W | 3000-8000 K / 70-97 |
| XGYT8B202SL-E18 | Double | 26 x 590 | 9 W x 2 | 36 W | S: 180-265 V; U: 85-265 V | 80-160 lm/W | 3000-8000 K / 70-97 |
| XGYT8B203SL-E24 | Double | 26 x 895 | 12 W x 2 | 60 W | S: 180-265 V; U: 85-265 V | 80-160 lm/W | 3000-8000 K / 70-97 |
| XGYT8B204SL-E36 | Double | 26 x 1199 | 18 W x 2 | 72 W | S: 180-265 V; U: 85-265 V | 80-160 lm/W | 3000-8000 K / 70-97 |
| XGYT8B205SL-E44 | Double | 26 x 1500 | 22 W x 2 | 116 W | S: 180-265 V; U: 85-265 V | 80-160 lm/W | 3000-8000 K / 70-97 |
All listed models use SMD2835 LEDs, 26 mm glass tubes and PC connector blocks with screw-fixing feet. PF options are >0.5 for S versions and >0.9 for U versions. Clear, milky or shatter-retention glass, cable or socket input, optional plug and cable length, interconnection, dimming and standby brightness are configuration options.
Product Description
Product Details
Product Construction
The fixture combines SMD2835 LEDs, 26 mm glass light bodies and fire-resistant PC end assemblies. Each end block supports the glass, provides a screw-mounting foot and houses the cable or socket terminal. Clear, milky and shatter-retention glass constructions are listed.
Selection & Installation Notes
Select the model by format, overall length, rated power, input range and glass construction. Fix both end assemblies to a suitable surface and route the selected cable or socket connection without loading the glass. For linked runs, calculate the total fixture load against the specified connector and circuit rating. Optional cable length, plug type, standby brightness and dimming require order-level configuration.
Recommended Application
Applications
- Workshops and Garages: Mount the fixture above workbenches, service bays and enclosed garage work areas.
- Retail Utility Areas: Provide linear general lighting in stockrooms, preparation zones and back-of-house spaces.
- Schools and Healthcare: Illuminate classrooms, corridors and non-procedure support areas with surface-mounted linear light.
- Libraries and Galleries: Provide broad linear illumination along reading zones, circulation paths and display areas.
- Hotels and Restaurants: Use the slim fixture in corridors, kitchens and service spaces requiring surface installation.
in touch
- No.5 Fenghuang Road Qianjiang Industrial Area Dingqiao Town Haining Zhejiang 314413 China
- +86-18358315743
- R.KOO@NEW-LIGHTS.COM
Frequently Asked Questions?
Find clear answers to common questions about product specifications, model selection, applications, and quotation requirements. For project-specific needs, send us your target market, required quantity, and key specifications.
Single-tube models use one lamp and double-tube models use two parallel lamps, producing different fixture widths, rated loads and fluorescent replacement references.
The PC connector blocks include screw-fixing feet for surface installation. Mount both ends to a suitable substrate without placing mechanical load on the glass tube.
Yes. Cable and socket inputs are listed options, with cable length and plug type selected for the required installation.
Yes, an interconnectable version is available. The permitted run depends on the configured connector, total fixture load and supply circuit rating.
The series lists clear glass, milky glass and shatter-retention glass options. Select the construction for the required diffusion and site glass-control policy.
Yes. Dimming and standby brightness are configured options; the standard standby level is 3 W, with 1-10 W available by configuration.