New Lights

Microwave Sensor Slim LED Panel

The Microwave Sensor Slim LED Panel combines a low-profile ceiling panel with a specified microwave-sensor option. Define the sensor, driver and operating behavior in the approved project specification.
  • Sensor-Equipped Panel Format: The ceiling-lighting assembly provides a defined location for a microwave-sensor component.
  • Slim Architectural Profile: The flat panel form keeps the ceiling composition visually restrained.
  • Project-Defined Behavior: The approved specification records the chosen sensor and driver response.
  • Reference-Based Coordination: The complete order code keeps the panel, control parts and installation requirements aligned.
SensorMicrowave occupancy detection
Construction9 mm side-emission housing
Panel formats595 x 595 / 620 x 620 / 295 x 1195 / 595 x 1195 mm
Rated power24-60 W; 50-60 W for 595 x 1195 mm
Luminous efficacy80-180 lm/W, customizable
CCT / CRI3000-6500K / Ra80 or Ra90
Input versionsS: 220-240 V; U: 100-240 V

Technical Specifications

Model Specifications

ModelDimensionsRated PowerEfficacyCCT RangeFrame ColorInput Versions
XGYPL-SE-6060-E40595 x 595 x 9 mm24-60 W (Isolated)80-180 lm/W3000-6500KWhiteS: 220-240 V / U: 100-240 V
XGYPL-SE-6262-E40620 x 620 x 9 mm24-60 W (Isolated)80-180 lm/W3000-6500KWhiteS: 220-240 V / U: 100-240 V
XGYPL-SE-30120-E40295 x 1195 x 9 mm24-60 W (Isolated)80-180 lm/W3000-6500KWhiteS: 220-240 V / U: 100-240 V
XGYPL-SE-60120-E60595 x 1195 x 9 mm50-60 W (Isolated)80-180 lm/W3000-6500KWhiteS: 220-240 V / U: 100-240 V

Detection range, hold time, daylight threshold and standby sequence are project-defined settings. Confirm the selected sensor and driver behavior on the approved sample before production.

Product Description

Product Details

Product Construction

A front lens and rear cover attach to a shallow perimeter chassis. Internal devices occupy positions defined by the selected build.

Selection & Installation Notes

Compare the catalogue code with the reflected plan. Record the opening, supports, device placement, cable path, interface and adjustment access, then approve the physical sample in the intended room. Compare related options in our project-grade LED panel range.

Recommended Application

Applications

  • Circulation Areas: Integrate the specified sensor panel into an approved indoor corridor lighting design.
  • Storage Rooms: Use the selected assembly in compatible indoor storage-room ceiling equipment.
  • Utility Spaces: Coordinate the panel, sensor and driver within an approved service-room installation.
  • OEM Control Projects: Build the confirmed sensor-panel configuration into a approved luminaire system.
Keep
in touch

Tell Us Your Market and Product Needs

Share your market, product interest, application, or estimated quantity. Our team can help you move faster from product selection to quotation and sample discussion.

By submitting this form, you ask New Lights Lighting Technology Co., Ltd. to use the information you provide to respond to your inquiry and manage related business communications. See our Privacy Policy. Optional marketing emails require the separate choice below.

Frequently Asked Questions?

Find clear answers to common questions about product specifications, model selection, applications, and quotation requirements. For project-specific needs, send us your target market, required quantity, and key specifications.

What detection range and hold time does the panel use?

Do not assume fixed values from the product name. Record the required settings in the approved specification and verify the selected sensor on a physical sample.

Can microwave sensing operate through partitions?

Do not assume a penetration distance or material response. Test the selected sensor in the actual room construction and approve the resulting detection zone.

Does the sensor provide a standard control sequence?

No single sequence should be assumed. Define the required trigger, delay, threshold, standby and driver behavior for the ordered system.

Are the sensor and driver supplied as one complete system?

Confirm the exact supplied components on the approved order. The panel, sensor, driver, wiring and installation accessories must be identified together.

Can similar sensor panels be interchanged?

Do not select by appearance alone. Match the complete reference, ceiling interface, driver, sensor, wiring and approved operating definition.

What should be tested before project approval?

Test the physical installation, detection zone, unwanted-trigger risk, operating sequence and driver response in the intended room before approval.

Featured Products

Scroll to Top

Send Us a Message

Leave your contact details and message. Our team will reply by email or through your preferred contact method.

By submitting this form, you ask New Lights Lighting Technology Co., Ltd. to use the information you provide to respond to your inquiry and manage related business communications. See our Privacy Policy. Optional marketing emails require the separate choice below.

Tell Us About Your Lighting Project

Share your product, application and purchasing requirements. Our lighting team will reply with suitable options and project support.

By submitting this form, you ask New Lights Lighting Technology Co., Ltd. to use the information you provide to respond to your inquiry and manage related business communications. See our Privacy Policy. Optional marketing emails require the separate choice below.