Replaceable-Tube LED Tri-Proof Fixture Housing
- Reusable Body During Relamping: Routine relamping replaces the light source while retaining the installed enclosure.
- Recess-Free Mounting: Metal rear brackets attach the linear body directly to ceilings or walls without a recessed cut-out.
- Independent Output Selection: Compatible G13 light sources allow light output and color temperature to be chosen separately from the enclosure.
- One- or Two-Lamp Layouts: Narrow and wide bodies support single-tube and double-tube lighting layouts.
| Housing Type | Shell for separate G13 tubes; no integrated LED board |
|---|---|
| Series | M / O / G / GS / MS / HS |
| Tube Format | 1 or 2 replaceable T8 tubes |
| Tube Load Range | 18, 36 or 58 W per tube |
|---|---|
| Housing Lengths | 656-1562 mm |
| Protection | IP65 configured assembly |
Technical Specifications
Model Specifications
| Model | Series | Housing Dimensions (W x H x L) | Rated Tube Load | Clips | Mount Distance |
|---|---|---|---|---|---|
| XGYT8TPM-E136 | M | 85 x 86 x 1263 mm | 1 x 36 W | 4 | 470 mm |
| XGYT8TPM-E236 | M | 120 x 86 x 1263 mm | 2 x 36 W | 4 | 470 mm |
| XGYT8TPO-E118 | O | 85 x 94 x 660 mm | 1 x 18 W | 4 | 316 mm |
| XGYT8TPO-E218 | O | 135 x 94 x 660 mm | 2 x 18 W | 4 | 316 mm |
| XGYT8TPO-E136 | O | 85 x 94 x 1268 mm | 1 x 36 W | 8 | 566 mm |
| XGYT8TPO-E236 | O | 135 x 94 x 1268 mm | 2 x 36 W | 8 | 566 mm |
| XGYT8TPO-E158 | O | 85 x 94 x 1562 mm | 1 x 58 W | 12 | 800 mm |
| XGYT8TPO-E258 | O | 135 x 94 x 1562 mm | 2 x 58 W | 12 | 800 mm |
| XGYT8TPG-E118 | G | 82 x 94 x 658 mm | 1 x 18 W | 4 | 447 mm |
| XGYT8TPG-E218 | G | 125 x 94 x 658 mm | 2 x 18 W | 4 | 447 mm |
| XGYT8TPG-E136 | G | 82 x 94 x 1266 mm | 1 x 36 W | 8 | 860 mm |
| XGYT8TPG-E236 | G | 125 x 94 x 1266 mm | 2 x 36 W | 8 | 860 mm |
| XGYT8TPGS-E118 | GS | 80 x 90 x 656 mm | 1 x 18 W | 6 | 470 mm |
| XGYT8TPGS-E218 | GS | 115 x 90 x 656 mm | 2 x 18 W | 6 | 470 mm |
| XGYT8TPGS-E136 | GS | 80 x 90 x 1260 mm | 1 x 36 W | 10 | 750 mm |
| XGYT8TPGS-E236 | GS | 115 x 90 x 1260 mm | 2 x 36 W | 10 | 750 mm |
| XGYT8TPGS-E158 | GS | 80 x 90 x 1560 mm | 1 x 58 W | 12 | 1015 mm |
| XGYT8TPGS-E258 | GS | 115 x 90 x 1560 mm | 2 x 58 W | 12 | 1015 mm |
| XGYT8TPMS-E118 | MS | 70 x 90 x 656 mm | 1 x 18 W | 4 | 470 mm |
| XGYT8TPMS-E218 | MS | 110 x 90 x 656 mm | 2 x 18 W | 4 | 470 mm |
| XGYT8TPMS-E136 | MS | 70 x 90 x 1260 mm | 1 x 36 W | 10 | 750 mm |
| XGYT8TPMS-E236 | MS | 110 x 90 x 1260 mm | 2 x 36 W | 10 | 750 mm |
| XGYT8TPMS-E158 | MS | 70 x 90 x 1562 mm | 1 x 58 W | 12 | 1015 mm |
| XGYT8TPMS-E258 | MS | 110 x 90 x 1562 mm | 2 x 58 W | 12 | 1015 mm |
| XGYT8TPHS-E136 | HS | 70 x 84 x 1262 mm | 1 x 36 W | 8 | 470 mm |
| XGYT8TPHS-E236 | HS | 110 x 84 x 1262 mm | 2 x 36 W | 8 | 470 mm |
Housing dimensions are shown as W x H x L. Rated tube load describes the separate lamp arrangement, not the input power of an integrated luminaire. Match the T8 tube length, G13 holders and single- or double-end wiring before assembly.
Product Description
Product Details
Product Construction
A PC or PS cover closes over a HIPS, ABS or PC base that carries the G13 lampholders. Plastic or stainless-steel side clips and rubber or silicone sealing options complete the housing assembly. The matched cover, base, seal, clips and cable entry form the documented IP65 configuration.
Selection & Installation Notes
Use the external dimensions and bracket-center spacing to select the M, O, G, GS, MS or HS profile, housing length and width. Verify the T8 tube length, G13 pin fit, input end and internal wiring before assembly. The standard offering is the housing; specify separate tube supply when a complete lamp-and-housing set is required.
Recommended Application
Applications
- Warehouse Aisles: Completed single- or double-tube assemblies provide linear lighting along storage and picking routes.
- Production Workshops: Sealed housing-and-tube assemblies provide general lighting above assembly, processing and maintenance work areas.
- Parking Garages: Surface-mounted housing-and-tube assemblies illuminate vehicle lanes, parking bays and pedestrian routes.
- Service Corridors: Single- and double-tube assemblies provide continuous lighting through utility passages and plant access routes.
in touch
- No.5 Fenghuang Road Qianjiang Industrial Area Dingqiao Town Haining Zhejiang 314413 China
- +86-18358315743
- R.KOO@NEW-LIGHTS.COM
Frequently Asked Questions?
Find clear answers to common questions about product specifications, model selection, applications, and quotation requirements. For project-specific needs, send us your target market, required quantity, and key specifications.
No. This page covers a housing with G13 lampholders for separate replaceable T8 tubes. Integrated SMD tri-proof luminaires are listed on a separate product page.
The standard offering on this page is the housing. Specify the required T8 tubes separately when a complete lamp-and-housing set is needed.
Yes. The internal wiring must match the selected tube, so confirm the tube input end and wiring diagram before assembly.
Start with the available mounting envelope and preferred housing cross-section, then match the single- or double-tube width, length, rated tube load and mount distance for the selected model.
IP65 applies to the documented complete assembly using the matched cover, base, sealing ring, clips and cable entry. Changing these parts changes the ingress-protection construction.
The product catalog displays CB, CE, ErP, RoHS and SAA marks for this tri-proof fixture family.