Standard IP65 LED Solar Flood Light

Separate-panel IP65 solar flood-light series with six die-cast aluminium fixture sizes for exterior area lighting where a local mains feed is unavailable. We manufacture six models with 8–30 W actual power, 150 lm/W listed efficacy, 8–35 W solar panels and clear glass optics for OEM/ODM programs.
  • Separate Panel Placement: Aim the flood head at the target area while positioning the matched panel for useful daylight.
  • Six Matched Sizes: Actual power steps from 8 W to 30 W are paired with 8 W to 35 W solar panels.
  • IP65 Aluminum Housing: The die-cast body, clear glass front and U-bracket form a fixed exterior flood-light assembly.
  • Listed 150 lm/W Efficacy: Use actual power with the listed efficacy when comparing the six configurations.
grade25–300 W
Efficacy150 lm/W
Solar panel8–35 W
ConstructionDie-cast aluminum / clear glass
ProtectionIP65

Technical Specifications

Model Specifications

Model No.GradeActual PowerLamp SizeEfficacySolar PanelPanel Size
XGYSFL-SL12-E2525W≥8W193 × 146 × 50150 lm/W8W235 × 350 × 17
XGYSFL-SL12-E4040W≥12W227 × 180 × 50150 lm/W12W290 × 350 × 17
XGYSFL-SL12-E6060W≥15W255 × 208 × 65150 lm/W18W400 × 350 × 17
XGYSFL-SL12-E100100W≥25W300 × 250 × 75150 lm/W25W530 × 350 × 17
XGYSFL-SL12-E200200W≥28W335 × 270 × 80150 lm/W30W630 × 350 × 17
XGYSFL-SL12-E300300W≥30W397 × 310 × 85150 lm/W35W680 × 350 × 17

Product Description

Product Details

Product Construction

The remote solar panel charges the battery independently of the aimed flood head. A die-cast aluminum body and clear glass front support heat transfer and optical protection while the U-bracket fixes the beam direction.

Selection & Installation Notes

Use actual power, efficacy and a lighting layout for selection; do not treat the 25–300 W grade as electrical input. Check panel size, year-round solar exposure, bracket loads, cable route and glare at the planned mounting height. For related integrated and split-panel formats, compare our solar flood lights.

Recommended Application

Applications

  • Loading Bay Aprons: Aim the flood head across loading approaches while placing the panel beyond roof shadow.
  • Parking Area Edges: Use a lighting layout to select fixture quantity, spacing and mounting height.
  • Building Perimeters: Mount the flood head along exterior walls and route the separate panel cable around the facade.
  • Remote Storage Yards: Add off-grid area lighting where a local mains feed is unavailable.
Keep
in touch

Tell Us Your Market and Product Needs

Share your market, product interest, application, or estimated quantity. Our team can help you move faster from product selection to quotation and sample discussion.

By submitting this form, you ask New Lights Lighting Technology Co., Ltd. to use the information you provide to respond to your inquiry and manage related business communications. See our Privacy Policy. Optional marketing emails require the separate choice below.

Frequently Asked Questions?

Find clear answers to common questions about product specifications, model selection, applications, and quotation requirements. For project-specific needs, send us your target market, required quantity, and key specifications.

Should the grade or actual power be used for selection?

Use actual power and the listed efficacy for electrical and output calculations. The 25–300 W values are grade names and are retained separately to avoid confusing them with consumption.

Will the listed solar runtime be the same in every season?

No. Actual operation depends on daylight hours, panel angle and shade, weather, temperature, battery condition, control mode and nightly activation. Validate the selected model at the intended site.

Can the panel and flood head face the same direction?

Not necessarily. Aim the flood head at the target area, but orient the separate panel for useful daylight and keep the cable route within the approved installation.

How is expected light output estimated?

Estimate initial output from actual power and the listed 150 lm/W efficacy, then verify quantity, spacing, mounting height and glare in a lighting layout. Do not calculate from the grade name.

What does the outdoor protection statement cover?

IP65 applies to the approved fixture housing. Cable joints, panel leads and wall penetrations need their own suitable sealing.

What can New Lights configure for an OEM/ODM program?

We can manufacture the approved actual-power step, housing size, panel, battery/controller, cable, labels and packaging after the sample is fixed.

Featured Products

Scroll to Top

Send Us a Message

Leave your contact details and message. Our team will reply by email or through your preferred contact method.

By submitting this form, you ask New Lights Lighting Technology Co., Ltd. to use the information you provide to respond to your inquiry and manage related business communications. See our Privacy Policy. Optional marketing emails require the separate choice below.

Tell Us About Your Lighting Project

Share your product, application and purchasing requirements. Our lighting team will reply with suitable options and project support.

By submitting this form, you ask New Lights Lighting Technology Co., Ltd. to use the information you provide to respond to your inquiry and manage related business communications. See our Privacy Policy. Optional marketing emails require the separate choice below.