New Lights

T5/T6 Internal-Driver LED Tubes

These G5 T5 and T6 LED tubes integrate the driver inside 16 or 19 mm lamp bodies for direct-AC linear lighting, with six lengths, discrete 5-22 W powers and single- or universal-voltage options. They suit correctly wired indoor fixtures used for office, retail, education and hospitality task lighting.
  • Flicker-Free Operation: The no-flicker IC circuit supports comfortable general lighting in occupied indoor spaces.
  • Multiple Optical Finishes: Clear, frosted and shatter-retention choices cover different diffusion and handling requirements by tube type.
  • Dimmable Versions Available: Dimmable models provide adjustable output for projects that require lighting control.
  • Rated Service Life: A 25,000-hour rated lifetime supports routine indoor replacement cycles.
Tube FormatsT5: Dia. 16 mm / T6: Dia. 19 mm
Length Range288 / 549 / 849 / 1000 / 1149 / 1449 mm
Rated Power5 / 9 / 12 / 16 / 18 / 22 W
Input & PFS: AC 180-265 V, PF >0.5 / U: AC 85-265 V, PF >0.9
Input MethodSingle-ended standard / double-ended configurable
Efficacy & CCT80-150 lm/W; 3000-8000 K
CRI & BeamCRI 70 / 80 / 90 / 95 / 97; 320 degrees

Technical Specifications

Model Specifications

Model No.TubeSize Dia. x L (mm)Rated / EqV.Input / PFEfficacyCCTCRI
XGYT5B301ID-E5T516 x 2885 W / 8 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B301ID-E5T619 x 2885 W / 8 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT5B302ID-E9T516 x 5499 W / 14 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B302ID-E9T619 x 5499 W / 14 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT5B303ID-E12T516 x 84912 W / 21 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B303ID-E12T619 x 84912 W / 21 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT5B304aID-E16T516 x 100016 W / 26 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B304aID-E16T619 x 100016 W / 26 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT5B304ID-E18T516 x 114918 W / 28 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B304ID-E18T619 x 114918 W / 28 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT5B305ID-E22T516 x 144922 W / 35 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97
XGYT6B305ID-E22T619 x 144922 W / 35 WS: 180-265 V / >0.5; U: 85-265 V / >0.980-150 lm/W3000-8000 K70 / 80 / 90 / 95 / 97

S denotes the listed single-voltage driver and U the universal-voltage driver. The input method, tube finish and end-cap construction must match the confirmed configuration and installation diagram.

Product Description

Product Details

Product Construction

These G5 bi-pin linear lamps place the LED board and power electronics inside a straight glass-based tube body. The paired series uses separate 16 mm T5 and 19 mm T6 mechanical platforms, with PC or aluminum end-cap construction selected for the confirmed configuration.

Selection & Installation Notes

Select the exact T5 or T6 model by diameter, length and discrete power, then match the single-voltage or universal-voltage driver and the ordered single- or double-ended input method. Direct-AC installation requires the fixture wiring to follow the supplied diagram, with the fluorescent ballast removed or bypassed as specified before the tube is energized.

Recommended Application

Applications

  • Office Task Lighting: Provide linear illumination above desks, work counters and circulation areas in correctly wired G5 fixtures.
  • Retail Shelving: Illuminate merchandise shelves, display cases and checkout work areas with compact T5 or T6 tube lengths.
  • Classrooms and Libraries: Support reading tables, teaching spaces and book-stack aisles with flicker-free linear lighting.
  • Hotel Service Areas: Light corridors, utility counters and back-of-house workspaces fitted with direct-AC linear fixtures.
Keep
in touch

Tell Us Your Market and Product Needs

Share your market, product interest, application, or estimated quantity. Our team can help you move faster from product selection to quotation and sample discussion.

By submitting this form, you ask New Lights Lighting Technology Co., Ltd. to use the information you provide to respond to your inquiry and manage related business communications. See our Privacy Policy. Optional marketing emails require the separate choice below.

Frequently Asked Questions?

Find clear answers to common questions about product specifications, model selection, applications, and quotation requirements. For project-specific needs, send us your target market, required quantity, and key specifications.

What is the difference between the T5 and T6 versions?

T5 models use a 16 mm diameter and frosted construction. T6 models use a 19 mm diameter and support clear, frosted or shatter-retention options within the confirmed configuration.

Does this internal-driver tube operate through the old fluorescent ballast?

No for the direct-AC configuration. The fluorescent ballast must be removed or bypassed and the fixture must be wired to the diagram supplied for the ordered tube.

Can the tube use single-ended or double-ended input?

Yes. The series supports a single-ended standard configuration and a configurable double-ended version; the lamp label and fixture wiring must use the same method.

What is the difference between the S and U driver options?

S identifies the listed AC 180-265 V version with PF above 0.5, while U identifies the AC 85-265 V universal-voltage version with PF above 0.9.

Which optical options are available for this series?

Available options cover 80-150 lm/W, 3000-8000 K, CRI 70, 80, 90, 95 or 97, and a 320-degree beam format. Confirm the selected combination for each order configuration.

Which certifications are available for these T5/T6 tubes?

The available certification set includes CE, CB, INMETRO, RoHS and ErP, with TUV-supported compliance available for confirmed configurations. The marks supplied must match the confirmed production configuration.

Featured Products

Scroll to Top

Send Us a Message

Leave your contact details and message. Our team will reply by email or through your preferred contact method.

By submitting this form, you ask New Lights Lighting Technology Co., Ltd. to use the information you provide to respond to your inquiry and manage related business communications. See our Privacy Policy. Optional marketing emails require the separate choice below.

Tell Us About Your Lighting Project

Share your product, application and purchasing requirements. Our lighting team will reply with suitable options and project support.

By submitting this form, you ask New Lights Lighting Technology Co., Ltd. to use the information you provide to respond to your inquiry and manage related business communications. See our Privacy Policy. Optional marketing emails require the separate choice below.