UV-A/BLB-Schwarzlicht-Leuchtstofflampen
- Fluorescence Visibility: The optical output reveals compatible fluorescent markings while limiting distracting visible lamp glow.
- Fixture Geometry Choice: Linear and folded shapes support both long housings and space-conscious equipment layouts.
- Separate Lamp Replacement: The light source can be serviced without replacing a suitable fixture enclosure.
- Defined Illumination Role: The lamp supplies excitation light while the complete instrument and operator determine the inspection result.
| Lampentyp | UV-A/BLB-Schwarzlicht-Leuchtstofflampe |
|---|---|
| Spitzenwellenlänge | 365 nm |
| Glas | Schwarzes Glas |
| Verfügbare Formen | T5, T8, T10, T12, PL-S und PL-L |
|---|---|
| Installation | Lampenform und Sockel auf die Fassung abstimmen |
| Betriebsgerät | Kompatibles externes Vorschaltgerät erforderlich |
Technische Daten
Modellspezifikationen
| Modell | Lampenform | Rohrdurchmesser (mm) | Gesamtlänge (mm) | Kappe / Sockel | Nennleistung |
|---|---|---|---|---|---|
| XGYT5-BLB-4W | T5 | 16 | 135.9 | G5 | 4 W |
| XGYT5-BLB-6W | T5 | 16 | 212.1 | G5 | 6 W |
| XGYT5-BLB-8W | T5 | 16 | 288.3 | G5 | 8 W |
| XGYT5-HO-BLB-15W | T5 HO | 16 | 288.3 | G5 | 15 W |
| XGYT5-BLB-14W | T5 | 16 | 549 | G5 | 14 W |
| XGYT5-BLB-21W | T5 | 16 | 849 | G5 | 21 W |
| XGYT5-BLB-28W | T5 | 16 | 1149 | G5 | Mit Projektblatt bestätigen |
| XGYT8-BLB-10W | T8 | 26 | 331 | G13 | 10 W |
| XGYT8-BLB-15W | T8 | 26 | 437.4 | G13 | 15 W |
| XGYT8-BLB-18W | T8 | 26 | 589.8 | G13 | 18 W |
| XGYT8-BLB-30W | T8 | 26 | 894.6 | G13 | 30 W |
| XGYT8-BLB-36W | T8 | 26 | 1199.4 | G13 | 36 W |
| XGYT8-BLB-58W | T8 | 26 | 1500 | G13 | 58 W |
| XGYT10-BLB-20W | T10 | 32 | 589.8 | G13 | 20 W |
| XGYT10-BLB-40W | T10 | 32 | 1199.4 | G13 | 40 W |
| XGYT12-BLB-20W | T12 | 38 | 589.8 | G13 | 20 W |
| XGYT12-BLB-40W | T12 | 38 | 1199.4 | G13 | 40 W |
| XGYPLS-5W-BLB | PL-S | 12 | 85 | G23 / 2G7 | 5 W |
| XGYPLS-7W-BLB | PL-S | 12 | 115 | G23 / 2G7 | 7 W |
| XGYPLS-9W-BLB | PL-S | 12 | 145 | G23 / 2G7 | 9 W |
| XGYPLS-11W-BLB | PL-S | 12 | 215 | G23 / 2G7 | 11 W |
| XGYPLS-13W-BLB | PL-S | 12 | 155 | GX23 / 2G7 | 13 W |
| XGYPLL-18W-BLB | PL-L | 18 | 225 | 2G11 | 18 W |
| XGYPLL-24W-BLB | PL-L | 18 | 320 | 2G11 | 24 W |
| XGYPLL-55W-BLB | PL-L | 18 | 535 | 2G11 | 55 W |
| XGYPLL-36W-BLB | PL-L | 18 | 415 | 2G11 | 36 W |
Produktbeschreibung
Produktdetails
Produktkonstruktion
Die Lampe kombiniert ein UV-A-Leuchtstoffsystem mit einem Schwarzglaskolben, der den größten Teil des sichtbaren Lichts absorbiert. Gerade T5-, T8-, T10- und T12-Versionen verwenden Zweistiftsockel, während PL-S- und PL-L-Versionen das Entladungsrohr zu einem kompakten Steckformat falten.
Hinweise zur Auswahl und Installation
Select the lamp by physical form, tube diameter, overall length and holder interface, then confirm the rated electrical specification and compatible external control gear for the final order reference. Plug-in base options require project confirmation because different holder interfaces are not interchangeable. Compare adjacent products in our UV-A and blacklight lamp range.
Empfohlene Anwendung
Anwendungen
- Document Fluorescence Viewers: Provides UV-A/BLB illumination in compatible equipment used to reveal fluorescent document features.
- Laboratory Fluorescence Viewing: Supports enclosed laboratory viewing equipment designed around a 365 nm blacklight source.
- Process Inspection Equipment: Excites fluorescent markers in compatible indoor inspection systems and viewing stations.
- Indoor Blacklight Fixtures: Serves replacement and OEM fixture programs that use straight or compact fluorescent blacklight lamps.
in Kontakt bleiben
- Nr. 5, Fenghuang Road, Industriegebiet Qianjiang, Stadt Dingqiao, Haining, Zhejiang 314413, China
- +86-18358315743
- R.KOO@NEW-LIGHTS.COM
Teilen Sie uns Ihre Markt- und Produktanforderungen mit
Teilen Sie uns Ihre Markt- und Produktinteressen, Anwendungsbereiche oder die voraussichtliche Menge mit. Unser Team unterstützt Sie dabei, den Weg von der Produktauswahl bis zum Angebot und zur Musterbesprechung schneller zu beschreiten.
Häufig gestellte Fragen?
Hier finden Sie klare Antworten auf häufig gestellte Fragen zu Produktspezifikationen, Modellauswahl, Anwendungsbereichen und Angebotsanforderungen. Bei projektspezifischen Anforderungen teilen Sie uns bitte Ihren Zielmarkt, die gewünschte Menge und die wichtigsten Spezifikationen mit.
Stimmen Sie zuerst physische Lampenform, Rohrdurchmesser, Gesamtlänge und Fassungschnittstelle ab. Bestätigen Sie anschließend elektrische Nennspezifikation und externes Betriebsgerät für die endgültige Bestellreferenz.
Diese Familie ist eine UV-A-Schwarzlichtquelle mit 365 nm und Schwarzglaskolben. Sie ist keine UV-C-Entkeimungslampe und darf nicht zur Desinfektion ausgewählt werden.
Nein. Sie liefert UV-A/BLB-Beleuchtung, die fluoreszierende Merkmale sichtbar machen kann. Die Authentifizierung hängt vom vollständigen Betrachtungssystem, den Referenzmerkmalen und dem vom Bediener verwendeten Verfahren ab.
Ja. Verwenden Sie kompatible Vorschaltgeräte für Leuchtstofflampen und die für die gewählte Lampenkonfiguration angegebene Fassung.
Nein. Bestätigen Sie für die Bestellung die genaue Steckfassung und Fassungschnittstelle, da unterschiedliche Sockelkonfigurationen nicht austauschbar sind.
Die exakte offizielle Produktseite nennt CE und RoHS. Bestaetigen Sie die geltende Zertifikatsdatei fuer bestelltes Modell und Zielmarkt.